Fomtec Enviro AIR is a novel fluorine free firefighting foam totally free from fluorinated surfactants and polymers. Fomtec Enviro AIR is especially designed to be an effective fluorine-free alternative for Aircraft Rescue and Fire Fighting (ARFF) fighting class B fires in aviation Kerosine jet fuel such as Jet A 1. Fomtec Enviro AIR should be used at 3% with fresh water for low expansion equipment such as monitors and handlines.

Features

 

New Generation Fluorine Free Foam

Low viscosity

ICAO Level B

100% Biodegradable

 

Description

 

Fomtec Enviro AIR is a novel fluorine free firefighting foam totally free from fluorinated surfactants and polymers. Fomtec Enviro AIR is especially designed to be an effective fluorine-free alternative for Aircraft Rescue and Fire Fighting (ARFF) fighting class B fires in aviation Kerosine jet fuel such as Jet A 1.  Fomtec Enviro AIR should be used at 3% with fresh water for low expansion equipment such as monitors and handlines.

 

Application

Fomtec Enviro AIR is intended for use on class B hydrocarbon Kerosene fuels.Fomtec Enviro AIR is especially suited whenever a fluorine-free alternative with high fire performance is required. Suitable for mobile firefighting by use of aspirating foam discharge devices such as foam branchpipes and monitors, where application rates and technique can be adjusted to the specifics of each incident. Or in systems designed for use with the product based on recommended minimum applications rates, application duration and discharge devices.It is compatible with all dry chemical powders and can be used in powder/foam twin agent systems.

Fire Performance & Foaming

The fire performance of this product has been measured and documented according to "International Approvals" stated in this document. The design parameters depend on type of system and application. The use of the product should follow design guidelines. The foaming properties are depending on equipment used and other variables such as water and ambient temperatures. Average expansion 8:1, average ¼ drainage time 6:00 minutes using UNI 86 test nozzle.

Equipment

Fomtec Enviro AIR can easily be proportioned at the correct dilution using conventional proportioning equipment. The equipment should be designed to the foam type.

Fomtec Enviro AIR should be used with aspirating foam discharge devices giving an expansion of more than 7:1 for optimal performance.

Compatibility

Fomtec Enviro AIR can be used together with foam compatible powders and other expanded foams. It is only intended for use with fresh water.

Fomtec Enviro AIR concentrate should not be mixed with other foam concentrates.

Typical data

Appearance

Clear to yellowish liquid

Specific gravity at 20°C

1,04 ± 0.01 g/ml

Viscosity at 20°C spindle #1, 60 rpm

30 mPas

pH

6,5 to 8,5

Freezing point

-25°C

Recommended storage temperature

-15 to 55°C

Suspended sediment (v/v)

Less than 0,2%

Environmental

Fomtec Enviro AIR is formulated using raw materials specially selected for their fire performance and their environmental profile. The product is totally free from fluorinated surfactants and polymers and other organohalogens, and therefore it does not contain any PFOS or PFOA. Fomtec Enviro AIR is 100% biodegradable. The handling of spills of concentrate or foam solutions should however be undertaken according to local regulations. Normally sewage systems can dispose foam solution based on this type of foam concentrate, but local sewage operators should be consulted.

Full details will be found in the Material Safety Datasheet (MSDS). For more detailed information please consult Fomtec Technical Advices FTA 40.

Storage / Shelf life

Stored in original unbroken packaging the product will have a long shelf life. Shelf life in excess of 10 years will be found in temperate climates. As with all foams, shelf life will be dependent on storage temperatures and conditions.

For storage recommendations and material compatibility please refer to our technical dossier FTA 20 addressing the topic.

Inspection/Testing/ Maintenance

The foam concentrate should be tested annually. The testing should be made by a suitable laboratory for analysis of foam concentrates and should measure: pH, specific gravity, expansion, drainage time. Storage containers should be inspected and reevaluated for the suitability of the storage location in regard to temperature fluctuations (temperature should be as stable as possible). Exposure to direct sunlight should be avoided.

Packaging

We supply this product in 25 litre and 5 US gallon cans, 200 litre and 55 US gallon drums, 1000 litre and 265 US gallon IBC containers and in bulk on special request.

 

Volume per piece

Packaging

Part no

Approx. Shipping weight*

Dimensions (mm) L x W x H

25 ltr

Can

11-6001-01

26,7 kg

295 x 260 x441

200 ltr

Drum

11-6001-02

212,5 kg

581x 581 x 935

1000 ltr

Container

11-6001-04

1080 kg

1200 x1000 x1150

5 US gal.

Can

 

20,58 kg

295 x 260 x 441

55  US   gal.

Drum

 

220,66 kg

581 x 581 x 935

265 US gal.

Container

 

1083,6 kg

1200 x1000 x1150

Bulk

Special request

 

 

 

*including packaging